1
0
mirror of synced 2025-12-21 02:51:29 -05:00
Files
airbyte/docs/integrations/destinations/clickhouse-deprecated.md
2025-07-10 12:23:57 -07:00

7.8 KiB

ClickHouse

:::warning The Clickhouse connector is outdated and does not use Destination v2 (typing and deduplication). As a result, it may not work well with large datasets or could have performance issues. Subscribe to the discussion to receive updates and learn more. :::

Features

Feature Supported?(Yes/No) Notes
Full Refresh Sync Yes
Incremental - Append Sync Yes
Incremental - Append + Deduped No
Namespaces Yes

Output Schema

Each stream will be output into its own table in ClickHouse. Each table will contain 3 columns:

  • _airbyte_ab_id: a uuid assigned by Airbyte to each event that is processed. The column type in ClickHouse is String.
  • _airbyte_emitted_at: a timestamp representing when the event was pulled from the data source. The column type in ClickHouse is DateTime64.
  • _airbyte_data: a json blob representing with the event data. The column type in ClickHouse is String.

Getting Started (Airbyte Cloud)

Airbyte Cloud only supports connecting to your ClickHouse instance with SSL or TLS encryption, which is supported by ClickHouse JDBC driver.

Getting Started (Airbyte Open Source)

Requirements

To use the ClickHouse destination, you'll need:

  • A ClickHouse server version 21.8.10.19 or above

Configure Network Access

Make sure your ClickHouse database can be accessed by Airbyte. If your database is within a VPC, you may need to allow access from the IP you're using to expose Airbyte.

Permissions

You need a ClickHouse user with the following permissions:

  • can create tables and write rows.
  • can create databases e.g:

You can create such a user by running:

GRANT CREATE ON * TO airbyte_user;
GRANT CREATE ON default * TO airbyte_user;
GRANT DROP ON * TO airbyte_user;
GRANT TRUNCATE ON * TO airbyte_user;
GRANT INSERT ON * TO airbyte_user;
GRANT SELECT ON * TO airbyte_user;
GRANT CREATE DATABASE ON airbyte_internal.* TO airbyte_user;
GRANT CREATE TABLE ON airbyte_internal.* TO airbyte_user;
GRANT DROP ON airbyte_internal.* TO airbyte_user;
GRANT TRUNCATE ON airbyte_internal.* TO airbyte_user;
GRANT INSERT ON airbyte_internal.* TO airbyte_user;
GRANT SELECT ON airbyte_internal.* TO airbyte_user;

You can also use a pre-existing user but we highly recommend creating a dedicated user for Airbyte.

Target Database

You will need to choose an existing database or create a new database that will be used to store synced data from Airbyte.

Setup the ClickHouse Destination in Airbyte

You should now have all the requirements needed to configure ClickHouse as a destination in the UI. You'll need the following information to configure the ClickHouse destination:

  • Host
  • Port
  • Username
  • Password
  • Database
  • Jdbc_url_params

Naming Conventions

From ClickHouse SQL Identifiers syntax:

  • SQL identifiers and key words must begin with a letter (a-z, but also letters with diacritical marks and non-Latin letters) or an underscore (_).
  • Subsequent characters in an identifier or key word can be letters, underscores, digits (0-9).
  • Identifiers can be quoted or non-quoted. The latter is preferred.
  • If you want to use identifiers the same as keywords or you want to use other symbols in identifiers, quote it using double quotes or backticks, for example, "id", id.
  • If you want to write portable applications you are advised to always quote a particular name or never quote it.

Therefore, Airbyte ClickHouse destination will create tables and schemas using the Unquoted identifiers when possible or fallback to Quoted Identifiers if the names are containing special characters.

Changelog

Expand to review
Version Date Pull Request Subject
1.1.0 2024-06-16 #61650 Migrate to new build flow + restrict connector to run on rootless permissions. Requires Airbyte >= 1.3.0.
1.0.0 2024-02-07 #34637 Update the raw table schema
0.2.5 2023-06-21 #27555 Reduce image size
0.2.4 2023-06-05 #27036 Internal code change for future development (install normalization packages inside connector)
0.2.3 2023-04-04 #24604 Support for destination checkpointing
0.2.2 2023-02-21 #21509 Compatibility update with security patch for strict encrypt version
0.2.1 2022-12-06 #19573 Update dbt version to 1.3.1
0.2.0 2022-09-27 #16970 Remove TCP port from spec parameters
0.1.12 2022-09-08 #16444 Added custom jdbc params field
0.1.10 2022-07-05 #13639 Change JDBC ClickHouse version into 0.3.2-patch9
0.1.8 2022-07-05 #13516 Added JDBC default parameter socket timeout
0.1.7 2022-06-16 #13852 Updated stacktrace format for any trace message errors
0.1.6 2022-05-17 #12820 Improved 'check' operation performance
0.1.5 2022-04-06 #11729 Bump mina-sshd from 2.7.0 to 2.8.0
0.1.4 2022-02-25 #10421 Refactor JDBC parameters handling
0.1.3 2022-02-14 #10256 Add -XX:+ExitOnOutOfMemoryError JVM option
0.1.1 2021-12-21 #8982 Set isSchemaRequired to false
0.1.0 2021-11-04 #7620 Add ClickHouse destination